Free Cloud, no subscriptionShips within 3 working daysOrder →

Home / Guides

SOK Monitor first start, screen by screen

You have the box, its two cables and a rack of SOK batteries. The screen of the box guides the rest, in English. Four steps lead to the first reading, and each message along the way has a plain meaning.

By the SOK Monitor team · 23 November 2026 · 4 min read

In short

  • Cable into a free RS485 port of the batteries first, USB-C power second.
  • The count “Sent N, heard N bytes” shows if the fault is in the cabling or in a battery version we have to add.
  • In a cabin without Wi-Fi the screen still shows the batteries, in turn with the Wi-Fi instructions.

Three items come out of the SOK Monitor parcel: the box with its colour screen, an RJ45 communication cable and a USB-C cable. Add a USB charger of your own, any phone charger will do. From there the screen guides you, in English.

Step 1: cable, then power

Connect the supplied cable between the box and a free RS485 port of your SOK batteries, usually on the last battery of the chain. The CAN port is not the right one, and an existing link to your inverter stays where it is. Power the box over USB-C only once the cable is in. The box never writes anything to the batteries, it reads.

Step 2: getting the box on your Wi-Fi

The first real screen is titled WIFI SETUP. It is a to-do list:

  • “1. On your phone, join the WiFi network” and, in colour, the network of the box: SokMonitor- followed by four characters. It is open, without a password.
  • “2. Open this page:” with an http:// address to type into the browser of your phone.
  • “3. Pick your home WiFi and press Save”. The page lists the networks in range. Choose yours (2.4 GHz), give the password, press Save.
SOK Monitor with the WIFI SETUP list on its screen
The WIFI SETUP list as the box shows it.

Last line of that screen: “No WiFi saved yet” on a new box. Once saved, the box restarts on your network. If instead WIFI SETUP returns after about forty seconds with “Cannot join:” and the name of your network, the box could not get in: a wrong password most of the time, sometimes a router too far from the batteries. Start again from point 1.

Step 3: the box looks for your batteries

Next comes a screen headed SOK MONITOR and LINK. It says “Waiting for the BMS”, then a yellow status message that can run over three lines, then the reminder “Cable in an RS485 socket (not CAN), free socket”.

SOK Monitor search screen reading No answer: check the cable and the port
The search screen when no battery has replied.

Messages that ask nothing of you

“Listening to the bus” comes first: for a few seconds the box only listens, in case another device is using the port. “Looking for the BMS” follows, with lines starting with “Trying” that flick past while the box tries the known dialects of this type of BMS. “Looking for other packs” is good news: a first battery has replied and the others are being counted. Allow a few minutes in all.

Messages that ask for a check

On the screenCause and remedy
“No answer: check the cable and the port”A complete pass without any reply. Reseat the cable at both ends, confirm it sits in an RS485 port and not CAN, try another RS485 port, check the battery is on.
“Unknown protocol: send us the report (Diagnostics)”Signals arrive, but not a BMS reply the box can recognise. Rule out the CAN port first. If the cable is right, send us the report.
“The BMS answers in a format not known yet: send us the report (Diagnostics)”Your battery replies properly, in a version we have not seen. The report lets us add it.
“Another device talks on this port: staying silent”The port is busy with another device, an inverter for instance. The box will not talk over it. Choose a free port.
“Another reader polls this bus: listening only”Something else already reads the batteries. The box follows silently and usually shows values. “Bus traffic not understood: send us the report” means it could not; “Bus silent: listening again” means the other device went quiet.
“No more answer: looking again”Readings had started, then stopped for a minute: a loose cable, or a battery switched off.

Sent and heard: where is the fault?

Near the bottom, the screen keeps a count: “Sent N, heard N bytes”. The first number is how many times the box has asked, the second how much has come back. When it reads heard 0 bytes, suspect the cable or the port, since nothing at all reaches the box. When “heard” is above zero and no link is made, the batteries do answer, in a way the box does not know yet. Then we need the report.

Step 4: your first reading

In large digits, the charge of the bank, with a coloured gauge and the count of packs. In the right-hand column: watts, volts, amps, hottest temperature (“C max”) and cell gap (“delta”, in mV). Then one small bar per battery, the energy of the day after “Today”, and the address of the box. The header reads CHARGING, DISCHARGING, IDLE or ALARM. This view holds twelve seconds, a CELLS view takes over for six (lowest and highest cell, spread, temperatures, charge of each pack), and the cycle repeats.

No Wi-Fi at the batteries

In a cabin or a shed there may be no network at all. The box reads the batteries anyway. Its screen shows the values for ten seconds, the WIFI SETUP list for ten seconds, and keeps alternating. That is normal with the latest firmware. Until the batteries answer, though, only WIFI SETUP is displayed.

The status LED

A blink every two seconds: reading. Quick, steady blinking: no answer from the batteries yet.

When to write to us, and with what

If the link is still not made, send us a photo of the search screen and the report file. The report is on the page of the box: open the Diagnostics tab and press Download report. Should the box need a fresh start, its firmware can be reinstalled over USB from a computer on sok-monitor.com/reset, using Chrome or Edge and a USB-C cable that carries data. This erases all settings, Wi-Fi included.

Common questions

Which port of the SOK battery does the cable go into?

A free RS485 port, usually on the last battery of the chain. Not the CAN port. The screen repeats it during the search: “Cable in an RS485 socket (not CAN), free socket”.

The count stays at “heard 0 bytes”. What should I check?

The cabling. Nothing comes back to the box: reseat the supplied cable at both ends, make sure it is in an RS485 port and that the battery is switched on.

“Heard” goes up but the batteries never appear. Why?

The batteries answer in a way the box does not know yet. Send us a photo of the screen and the report from the Diagnostics tab, and we add your version.

My cabin has no Wi-Fi. Is the box of any use there?

Yes. Once the batteries answer, the screen shows them and alternates every ten seconds with the Wi-Fi instructions. The web page, Home Assistant and the Cloud need a network.

What does the reinstall on /reset erase?

The settings of the box, Wi-Fi included. Nothing on the batteries, since the box never writes to them.

SOK Monitor box with screen showing battery charge, voltage and currentRJ45 communication socket and USB-C power on the SOK Monitor
The SOK Monitor box, real photos. Size, ports and specifications →
Hands-on

See it on your own system

Your SOK batteries, from anywhere in the world

Order SOK Monitor today. Prepared and tested for your rack, dispatched within 3 working days.

Plug & play: working in about a minute

Order for €59Ships within 3 working days · free cancellation until dispatch
Follow us on FacebookTips, news and real installations from our customers.
Follow